$104.45

Original: $348.17

-70%
Viessmann Plate heat exchanger flushing system Vitodens 100/200-W

$348.17

$104.45

The Story

Please call to check availability before ordering Live Chat / 01985 850982

Flushing the plate heat exchanger system for Viessmann Vitodens and Vitopend involves the use of a cleaning plate and seals. PWT Flushing System Procedure: 1. Follow the service instructions for the boiler to remove the plate heat exchanger. 2. Place the provided profile seals (A) into the cleaning plate (B). 3. Attach the plate heat exchanger (C) onto the cleaning plate (B) as shown in the illustration. 4. Connect the plate heat exchanger with the cleaning plate to the flushing device, taking note of the connection markings and flow direction. 5. Flush the plate heat exchanger with an appropriate cleaning agent against the normal flow direction for approximately 30 minutes. Depending on the type and amount of deposits, you may need to extend or repeat the rinsing process. 6. Thoroughly rinse the plate heat exchanger with water after cleaning. 7. Remove the plate heat exchanger (C) from the cleaning plate (B). 8. Apply grease to new profile seals (A) and insert them into the boiler. 9. Reinstall the plate heat exchanger and reassemble the boiler.

Description

Please call to check availability before ordering Live Chat / 01985 850982

Flushing the plate heat exchanger system for Viessmann Vitodens and Vitopend involves the use of a cleaning plate and seals. PWT Flushing System Procedure: 1. Follow the service instructions for the boiler to remove the plate heat exchanger. 2. Place the provided profile seals (A) into the cleaning plate (B). 3. Attach the plate heat exchanger (C) onto the cleaning plate (B) as shown in the illustration. 4. Connect the plate heat exchanger with the cleaning plate to the flushing device, taking note of the connection markings and flow direction. 5. Flush the plate heat exchanger with an appropriate cleaning agent against the normal flow direction for approximately 30 minutes. Depending on the type and amount of deposits, you may need to extend or repeat the rinsing process. 6. Thoroughly rinse the plate heat exchanger with water after cleaning. 7. Remove the plate heat exchanger (C) from the cleaning plate (B). 8. Apply grease to new profile seals (A) and insert them into the boiler. 9. Reinstall the plate heat exchanger and reassemble the boiler.

You may also like

NEW
Thumbnail 1

Viessmann Tee piece for DHW Cylinder no pump included

$91.89

NEW
Thumbnail 1

Viessmann Connection pipes for install left/right 49 - 99 kW

$41.13

NEW
Thumbnail 1

Viessmann Connection pipe bends for install top/bottom 49 - 99 kW

$69.40

NEW
Thumbnail 1

Viessmann DHW Cylinder Connection pipes no pump 80 - 99 kW - 7348934

$193.32

NEW
Thumbnail 1

Viessmann Connection pipes for install left/right 120 - 150 kW

$84.19

-70%NEW
Thumbnail 1

Viessmann Freestanding Frame with heating circuit connection set 49 - 150 kW

$598.26

$179.48

NEW
Thumbnail 1

Viessmann Connection pipe bends for install top/bottom 120 - 150 kW

$106.03

NEW
Thumbnail 1

Viessmann Tee piece for DHW Cylinder no pump included 120 - 150 kW

$242.91

NEW
Thumbnail 1Thumbnail 2

Viessmann Vitocal 100-A Space-saving Monobloc Heat Pump Outdoor 6 kW to 16 kW

$5,772.01

NEW
Thumbnail 1

Viessmann Drain set for condensation run-off via pipe for Outdoor Unit - ZK04096

$15.37

NEW
Thumbnail 1

Viessmann Pre-plumbing jig with valves - connection to right Compact

$300.74

NEW
Thumbnail 1

Viessmann DHW cylinder temperature sensor

$27.64